Overhang & Undercut Design in Medical CNC: Feasibility Rules

Jack Lie CNC machining expert

Specialize in CNC Milling, CNC Turning, 3D Printing, Urethane Casting, and Sheet Metal Fabrication Services.


When a medical device drawing lands on an engineer’s desk, the geometries that slow everyone down are usually the same few: an internal thread that must lock a titanium stem into a taper, a dovetail that holds a trial implant, a blind pocket that should carry a resorbable spacer. These are undercuts. Undercuts and overhangs appear constantly in medical parts because the human anatomy they replicate is full of negative space, and because a bone-contacting implant has to do more than hold a tolerance; it has to elicit a specific biological response on its surface. The feasibility of those features decides whether a part is made in two operations or six, whether it needs a five-axis cell or an EDM finish, and ultimately whether the quoted price holds.

Why Undercuts and Overhangs Are Everywhere in Medical Parts

Orthopedic and dental implants are, in most cases, made subtractively. A review of patient-specific reverse shoulder arthroplasty implants states plainly that computer-assisted machining is the most common manufacturing method for orthopedic implants, with metal removed from a titanium blank and the contours carved down to the final shape. The same source notes that locking threads, Morse tapers, and interfacing components can be machined into the implant at this stage. Those three features are precisely the undercuts that make a medical drawing hard to machine: a Morse taper is a shallow cone, the locking threads are internal, and the modular attachment surfaces sit recessed behind a shoulder. None of them is reachable by a standard end mill plunging from the top.

Why draw them at all? Because the implant must both lock mechanically and integrate chemically. The Morse taper holds a modular head on a stem without fasteners; locking threads let a screw hold a plate against bone; the recessed surface is often the region later roughened for osseointegration. These are not decorative undercuts; they carry load, and the biological burden of the part.

What an Undercut Actually Means for the Cutting Tool

An undercut is any feature whose entrance is narrower than the cavity behind it, or whose geometry faces the tool from an angle the spindle cannot reach. For a standard milling operation, a three-axis spindle can reach any surface that lies in the tool’s line of sight. Everything else is an undercut. Overhangs are the mirror problem: a feature that sticks out over a void, requiring the tool to reach underneath it, often with a long neck that flexes as it cuts.

For feasibility, features fall into four practical classes:

  • Reachable with a standard tool: an open slot or a shallow groove with clearance above.
  • Reachable with a specialty tool: an internal groove that needs a lollipop cutter or a side-lock end mill whose neck fits through the opening.
  • Reachable only with added axes: a feature angled in space that needs a fourth or fifth rotary axis to orient the part.
  • Not reachable by milling at all: a deep blind undercut that no tool can enter, which forces a process change to EDM, broaching, or a split-line design.

The classification changes the machine, the fixture, the tooling, and the price: a part that looks identical on paper can be a three-axis job to one shop and a five-axis-plus-EDM job to another.

Feasibility Rules for Overhang and Undercut Geometry

A few numerical rules of thumb separate a machinable design from a fragile one. These come from general DFM practice rather than clinical literature, but they hold on medical parts as much as on any machined component.

The first rule concerns reach. An undercut’s depth must stay within the effective reach of the cutter, which is the length of the cutting head plus the usable neck, not the tool’s overall length. Deep undercuts push the cutter toward a long, unsupported neck; longer unsupported lengths reduce rigidity and increase cutting deflection, which shows up as chatter marks and wandering tolerances on a surface that may later interface with bone.

The second rule concerns the depth-to-diameter ratio. As a guideline, a ratio up to about two to three times the tool diameter cuts stably at standard feeds and speeds. From three to four times, the risk rises and operators typically reduce the feed rate by 20–30% and take lighter passes. Above four to five times, chatter becomes a real hazard and the toolpath, feed, and spindle speed need full reassessment. Beyond roughly five times the diameter, the feature is usually better served by EDM or by redesigning the geometry.

The third rule is about clearance around the feature. Design guides commonly recommend providing at least about 3 mm of vertical space above an undercut so the tool has room to move in and out, and keeping a minimum wall thickness on the order of 0.8 mm to avoid deformation during machining. Adjacent walls can restrict tool movement even when the cutting head reaches the feature; a common screening guideline is to leave opposing-wall clearance of roughly four times the undercut depth. These are screening numbers, not guarantees, but they catch the worst cases early.

The Medical Twist: Surface Integrity Is a Design Input

In most machining, surface finish is a cosmetic or a wear concern. In medical parts it is a biological variable, and this is where undercut design stops being a purely mechanical problem.

A machined titanium surface, by itself, is not friendly to the tissue it will touch. A review of reverse shoulder implants notes that a machined implant has a smooth finish that is not conducive to integration with surrounding tissue, and that postprocessing is required to roughen the bone-contacting surface. The mechanism is well documented: craters on the order of 30–100 µm in diameter are preferentially colonized by osteoblasts, and these craters resemble the resorption pits left by osteoclasts during bone remodeling. Roughness modulates more than attachment: cells on microrough surfaces show increased markers of osteoblastic differentiation, and microrough titanium substrates raise the production of angiogenic factors such as VEGF-A and FGF2, supporting the vascular supply an implant needs.

Roughened and machined surfaces are not simply better or worse. One review points out that roughened titanium surfaces promote rapid but thin bone formation, whereas smooth, machined surfaces support greater volumes of bone, albeit more slowly; osteoblasts differentiate faster on roughened surfaces at the expense of proliferation. At the nanoscale, modifications in the 1–100 nm range, including laser ablation, improve protein absorption and osteoblast adhesion. The clinical takeaway is that the intended surface response is engineered, not incidental.

This matters for undercuts for a direct reason: a surface that is hard for a cutting tool to reach is also hard for a finishing process to reach. If the design intent is a microrough bone-contacting surface inside a deep recess, the same geometry that forced a long-neck cutter will force a plasma spray, grit blasting nozzle, or laser to reach the same spot, and the finish will be uneven or inaccessible where it matters most. Undercut placement, in other words, sets a constraint on the postprocessing that creates the biological surface. Weighing a feature’s position early is not optional for a part that must osseointegrate.

Designing to Keep Undercuts Machinable

The practical design moves are well established. Where a function permits, a shallower groove or a more accessible geometry simplifies machining and removes cost. Where the undercut is unavoidable, the design should give the tool what it needs: enough opening for a lollipop cutter’s neck to pass through, clearance above the feature, and a wall thick enough to hold its shape. Features that face in from the side are candidates for a five-axis cell, and when an undercut is genuinely unreachable, the options are a process change to wire or sinker EDM, a broach, or splitting the part along a joint line and joining the halves—an approach medical assemblies already use for modular implants. Secondary processes also have a place, since a machined implant that later needs a roughened bone surface may combine a milled geometry with an ablated or etched texture rather than rely on one process alone.

A Practical Vetting Workflow

Before quoting or ordering a medical part with complex undercuts, run the drawing through a short checklist. Identify every internal thread, taper, dovetail, and blind pocket. For each, ask whether a standard tool can reach it, what the depth-to-diameter ratio is, how much vertical clearance exists above it, and what surface treatment the bone-contacting regions will need. Mark any feature that combines a deep reach with a required surface finish, because that pairing is where cost and failure risk concentrate. If a feature cannot be reached by any tool, decide early between EDM, a split line, or a design change rather than discovering the problem after the first batch. It is cheaper and faster to hand the drawing to the machine shop early—ideally with the surface-finish requirement spelled out—than to force a conversation after tooling has been cut.

Cost and Failure Drivers to Flag Early

The drivers are predictable. Deep undercuts raise cost through specialty tooling, longer cycle times, reduced feed rates, and the risk of scrapped parts from chatter. Features that need a fifth axis raise the hourly rate of the machine doing the work. A bone-contacting surface inside an unreachable recess forces either a postprocessing compromise that may hurt osseointegration or a redesign. And every feature that cannot be measured—a taper or groove a CMM probe cannot reach—adds risk, because inspection is part of the medical quality record. None of this is a reason to avoid undercuts; medical parts need them.

Feasibility Is a Conversation, Not a Guess

Undercuts and overhangs are not design mistakes in medical machining; they are the geometry of anatomy and of mechanical locking. The feasibility question is whether each feature can be reached by a tool with acceptable rigidity, whether its depth and clearance follow the standard rules of thumb, and whether the surface the part must present to bone can still be finished where it is needed. Reviewed early, against a clear checklist and with the surface requirement in hand, an undercut-heavy medical part is a solvable, quotable job rather than a surprise.

Feel free to contact us: [email protected]